A4T
AT4
Nominal pumping speed (50Hz) m3/h 4
Pumping speed at atmospheric pressure (50Hz) m3/h 3,6
Final pressure (without the gasballast) hPa <2
Final pressure (with the gasballast) hPa -
Final pressure for version AT…A hPa <30
Noise level (measured 1m from the outlet side) dB(A) 59
Motor rating (for 50Hz) kW 0,1** 0,1*
Pump oil filling l 0,06
Weight (approx.) kg 5,6
Oil separator pressure hPa <1500
Oil temperature ◦C <100

*) Single-phase power supply
**) Three-phase power supply
AT4C 1faz
1
AT6B
AT6B
Nominal pumping speed (50Hz) m3/h 6
Pumping speed at atmospheric pressure (50Hz) m3/h 6,4
Final pressure (without the gasballast) hPa <3
Final pressure (with the gasballast) hPa <3
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 65
Motor rating (for 50Hz) kW 0,3** 0,3*
Pump oil filling l 0,15
Weight (approx.) kg 19*/18**
Oil separator pressure hPa <1500
Oil temperature ◦C <100

*) Single-phase power supply
**) Three-phase power supply
AT6B
1
AT8
AT8
Nominal pumping speed (50Hz) m3/h 8
Pumping speed at atmospheric pressure (50Hz) m3/h 7,6
Final pressure (without the gasballast) hPa <2
Final pressure (with the gasballast) hPa <3
Final pressure for version AT…A hPa <25
Noise level (measured 1m from the outlet side) dB(A) 59
Motor rating (for 50Hz) kW 0,35** 0,35*
Pump oil filling l 0,25
Weight (approx.) kg 11
Oil separator pressure hPa <1500
Oil temperature ◦C <100

*) Single-phase power supply
**) Three-phase power supply
AT8 3faz
1
AT10B
AT10B
Nominal pumping speed (50Hz) m3/h 12
Pumping speed at atmospheric pressure (50Hz) m3/h 10,5
Final pressure (without the gasballast) hPa <3
Final pressure (with the gasballast) hPa <3
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 65
Motor rating (for 50Hz) kW 0,55** 0,55*
Pump oil filling l 0,15
Weight (approx.) kg 18*/17**
Oil separator pressure hPa <1500
Oil temperature ◦C <100

*) Single-phase power supply
**) Three-phase power supply

 

 

 

AT10B
1
AT21
AT21 / AT21A
Nominal pumping speed (50Hz) m3/h 21
Pumping speed at atmospheric pressure (50Hz) m3/h 18
Final pressure (without the gasballast) hPa <2
Final pressure (with the gasballast) hPa -
Final pressure for version AT…A hPa <20
Noise level (measured 1m from the outlet side) dB(A) 70
Motor rating (for 50Hz) kW 0,75** 1,1*
Pump oil filling l 0,3
Weight (approx.) kg 28*/20**
Oil separator pressure hPa <1500
Oil temperature ◦C <100

*) Single-phase power supply
**) Three-phase power supply
AT21
1
AT21B
AT21B
Nominal pumping speed (50Hz) m3/h 23
Pumping speed at atmospheric pressure (50Hz) m3/h 21
Final pressure (without the gasballast) hPa <1
Final pressure (with the gasballast) hPa <3
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 70
Motor rating (for 50Hz) kW 0,75**0,75*
Pump oil filling l 0,5
Weight (approx.) kg 27*/25**
Oil separator pressure hPa <1500
Oil temperature ◦C <100

*) Single-phase power supply
**) Three-phase power supply

AT21B
1
AT40B
AT40B
Nominal pumping speed (50Hz) m3/h 35
Pumping speed at atmospheric pressure (50Hz) m3/h 35
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <1
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 67
Motor rating (for 50Hz) kW 0,75
Pump oil filling l 1,4
Weight (approx.) kg 37
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT40B
1
AT63B
AT 63B
Nominal pumping speed (50Hz) m3/h 57
Pumping speed at atmospheric pressure (50Hz) m3/h 52
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <2
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 70
Motor rating (for 50Hz) kW 1,5
Pump oil filling l 2,2
Weight (approx.) kg 67
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT63B
1
AT100B
AT100B
Nominal pumping speed (50Hz) m3/h 92
Pumping speed at atmospheric pressure (50Hz) m3/h 80
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <2
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 70
Motor rating (for 50Hz) kW 3
Pump oil filling l 2,2
Weight (approx.) kg 84
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT100B
1
AT160B
AT160B
Nominal pumping speed (50Hz) m3/h 160
Pumping speed at atmospheric pressure (50Hz) m3/h 155
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <2
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 75
Motor rating (for 50Hz) kW 4
Ölmenge l 6
Weight (approx.) kg 172
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT 160B IE3
1
AT250B
AT250B
Nominal pumping speed (50Hz) m3/h 250
Pumping speed at atmospheric pressure (50Hz) m3/h 230
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <2
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 80
Motor rating (for 50Hz) kW 5,5
Pump oil filling l 6
Weight (approx.) kg 200
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT250B
1
T250B
T250
Nominale Pumpgeschwindigkeit (50Hz) m3/h 260 (50Hz) 310 (60Hz)
Pumpgeschwindigkeit bei dem atmosphärischen Druck (50Hz) m3/h 250 (50Hz) 300 (60Hz)
Enddruck (ohne Gasballast) hPa <0,3
Enddruck (mit Gasballast) hPa <1
Enddruck für Version AT…A hPa -
Lärmpegel (von der Ausgangsseite in Entfernung 1m) dB(A) 74 (50Hz) 77 (60Hz
Leistung des Elektromotors (bei 50Hz) kW 5,5 (50Hz) 6,6 (60Hz)
Ölmenge l 9
Gewicht kg 256
Druck im Ölabscheiderkasten hPa <1500
Öltemperatur ◦C <100
T300 T250 IE3
1
AT300
T300
Nominal pumping speed (50Hz) m3/h 305 (50Hz) 360 (60Hz)
Pumping speed at atmospheric pressure (50Hz) m3/h 300 (50Hz) 350 (60Hz)
Final pressure (without the gasballast) hPa <0,3
Final pressure (with the gasballast) hPa <1
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 74 (50Hz) 77 (60Hz
Motor rating (for 50Hz) kW 7,5 (50Hz) 9(60Hz)
Pump oil filling l 9
Weight (approx.) kg 253
Oil separator pressure hPa <1500
Oil temperature ◦C <100
T300 T250 IE3
1
AT400B
AT400B
Nominal pumping speed (50Hz) m3/h 400
Pumping speed at atmospheric pressure (50Hz) m3/h 370
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <2
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 85
Motor rating (for 50Hz) kW 11
Pump oil filling l 17
Weight (approx.) kg 440
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT 400B IE3
1
AT630B
AT630B
Nominal pumping speed (50Hz) m3/h 630
Pumping speed at atmospheric pressure (50Hz) m3/h 560
Final pressure (without the gasballast) hPa <0,5
Final pressure (with the gasballast) hPa <2
Final pressure for version AT…A hPa -
Noise level (measured 1m from the outlet side) dB(A) 85
Motor rating (for 50Hz) kW 15
Pump oil filling l 17
Weight (approx.) kg 545
Oil separator pressure hPa <1500
Oil temperature ◦C <100
AT630B

Design and operation

The pumping unit is composed of a cylinder (1), rotor with vanes (2), two end plates with bearings (3) as well as an inlet connecting port with a cut-off valve (4). The pumping unit is connected to the

separator via the outlet of the cylinder (5). The oil separator is designed as aluminum casting in the form of a double-chamber box.

The lower chamber serves as an oil container, where operating oil. The upper part of it is fitted with outlet filters (oil mist filters).

The torque from the electric motor is transmitted via a coupling (6). Three-phase or single-phase electric motors were used as a drive for pumps. Thanks to the pump being fitted with a gas ballast, it is possible to pump the air containing water vapor.

A safety anti – suckback valve installed on the inlet flange. The lubricating system works in a closed cycle. Oil hold by outlet filters returns automatically to this system. Pumps are cooled with air.

schemat

 Applications

  • meat and cured meat products processing appliances
  • meat fragmenting appliances
  • can-closing systems
  • clipping machines
  • central vacuum installations
  • suction-transportation appliances
  • load lifting devices
  • partial vacuum sewage systems
  • appliances for degassing, filtering off and filtering
  • vacuum chambers for disinfecting
  • oil and other fluid filtering off appliances to working machines, cars etc.
  • chambers to be used for tests in aviation
  • vacuum packing machines
  • packing lines
  • packages forming appliances
  • appliances for degassing and vacuum drying
  • in education for demonstration of phisical phenomena in vacuum environment

Appropriation and operation modes

The AT pumps are designed for operation at the ambient temperatures  of 5 to 35°C. The pumps are fitted with a very effective  separation system, which separates oil mist from the outlet air. Thanks to this feature they do not pollute the environment with oil mist. They can be used for pumping pure air or other inert gases. When equipped with a WF filter, air with dust or solid particles can be pumped as well.

Operation modes:

AT4C, AT8, AT21 – powrót oleju podczas postoju; tylko praca przerywana

T4CA, AT6B, AT8A, AT10B, AT21A, AT21B – powrót oleju podczas pracy pompy; możliwa praca ciągła lub przerywana

AT40B, AT50B, AT63B, AT100B, AT160B, AT250B,  AT400B, AT630B, T250, T300 – powrót oleju podczas pracy przez zawór pływakowy; możliwa praca ciągła lub przerywana.

Admissible frequency of pump starts:

AT4C, AT8 –1 ÷ 10 minutes operation, 1 minute break

AT6B ÷ AT100B –  no more than 1 start in a minute

AT21 – 1 ÷ 15 minutes operation, 1 minute break

AT160B ÷ AT630B, T250, T300 – no more than 1 start in 10 minutes

Operation features

  • reliable operation in the whole range of fore vacuum
  • direct drive
  • clean outlet air
  • silent operation and low vibration
  • built in cut-off valve
  • air cooling
  • possible to adjust to various types of power supply

Options

Vacuum pumps AT40B, AT50B, AT63B, AT100B, AT160B, AT250B, AT400B, AT630B T250, T300

 have to be secured extra with additional elements as follows:

  • oil level sensor
  • oil temperature sensor
  • oil separator pressure sensor
  • bimetallic thermostat
charakt ang dwa

Design and operation

The pumping unit is composed of a cylinder (1), rotor with vanes (2), two end plates with bearings (3) as well as an inlet connecting port with a cut-off valve (4). The pumping unit is connected to the

separator via the outlet of the cylinder (5). The oil separator is designed as aluminum casting in the form of a double-chamber box.

The lower chamber serves as an oil container, where operating oil. The upper part of it is fitted with outlet filters (oil mist filters).

The torque from the electric motor is transmitted via a coupling (6). Three-phase or single-phase electric motors were used as a drive for pumps. Thanks to the pump being fitted with a gas ballast, it is possible to pump the air containing water vapor.

A safety anti – suckback valve installed on the inlet flange. The lubricating system works in a closed cycle. Oil hold by outlet filters returns automatically to this system. Pumps are cooled with air.

schemat

 Applications

  • meat and cured meat products processing appliances
  • meat fragmenting appliances
  • can-closing systems
  • clipping machines
  • central vacuum installations
  • suction-transportation appliances
  • load lifting devices
  • partial vacuum sewage systems
  • appliances for degassing, filtering off and filtering
  • vacuum chambers for disinfecting
  • oil and other fluid filtering off appliances to working machines, cars etc.
  • chambers to be used for tests in aviation
  • vacuum packing machines
  • packing lines
  • packages forming appliances
  • appliances for degassing and vacuum drying
  • in education for demonstration of phisical phenomena in vacuum environment

Appropriation and operation modes

The AT pumps are designed for operation at the ambient temperatures  of 5 to 35°C. The pumps are fitted with a very effective  separation system, which separates oil mist from the outlet air. Thanks to this feature they do not pollute the environment with oil mist. They can be used for pumping pure air or other inert gases. When equipped with a WF filter, air with dust or solid particles can be pumped as well.

Operation modes:

AT4C, AT8, AT21 – powrót oleju podczas postoju; tylko praca przerywana

T4CA, AT6B, AT8A, AT10B, AT21A, AT21B – powrót oleju podczas pracy pompy; możliwa praca ciągła lub przerywana

AT40B, AT50B, AT63B, AT100B, AT160B, AT250B,  AT400B, AT630B, T250, T300 – powrót oleju podczas pracy przez zawór pływakowy; możliwa praca ciągła lub przerywana.

Admissible frequency of pump starts:

AT4C, AT8 –1 ÷ 10 minutes operation, 1 minute break

AT6B ÷ AT100B –  no more than 1 start in a minute

AT21 – 1 ÷ 15 minutes operation, 1 minute break

AT160B ÷ AT630B, T250, T300 – no more than 1 start in 10 minutes

Operation features

  • reliable operation in the whole range of fore vacuum
  • direct drive
  • clean outlet air
  • silent operation and low vibration
  • built in cut-off valve
  • air cooling
  • possible to adjust to various types of power supply

Options

Vacuum pumps AT40B, AT50B, AT63B, AT100B, AT160B, AT250B, AT400B, AT630B T250, T300

 have to be secured extra with additional elements as follows:

  • oil level sensor
  • oil temperature sensor
  • oil separator pressure sensor
  • bimetallic thermostat
charakt ang dwa

Pump stations

1
SR500
SR 500
Roots pump efficiency m3/h 500
Rotary pump efficiency m3/h 250
Ultimate vacuum hPa 1 x 10-2
max. pumping speed m3/h 450
Root's pump motor power kW 1,5
Rotary pump motor power kW 7,5
Weight kg 350
Power supply V/Hz 400/50
Noise level dB (A) 80
Root's pump oil capacity liter 1,3
Rotary pump oil capacity liter 6
Intake nozzle size - NW100
General dimensions mm 1040 x 670 x 1003
INTENDED USE
The pumping unit is intended for use in high-efficiency vacuum processes with heavy air and chemically inert gases load.

It can be used in::

  • vacuum packing lines and systems,
  • central vacuum systems,
  • metallurgy,
  • vacuum furnaces,
  • welders,
  • vacuum locks,
  • pre-vacuum units for diffusion and turbomolecular pumps,
  • highly-efficient leak detectors.

FEATURES

  • compact design,
  • application of Root’s blower with by-pass valve allows for its simultaneous switching on with a rotary pump and operation within the atmospheric pressure to final vacuum range,
  • application of the rotary pump with integrated safety valve and the oil mist filter (clean air is received at the outlet),
  • short pumping time,
  • noise level below 80 dB(A).